ID:22868 Reference clock inputs of all IPs in the Dynamic Reconfiguration group must be driven by the same system clock IP. IPs in the Reconfiguration group hierarchy '<DrGroup>' are driven by different system clock IP:

CAUSE: Reference clock inputs of IPs in the Dynamic Reconfiguration group are driven by different system clock IPs.

ACTION: Make sure that reference clock inputs of all IPs in the Dynamic Reconfiguration group are driven by the same system clock IP.