ID:14575 I/O "<name>" with "<name>" I/O standard and requiring termination, should connect to an OCT block in POD calibration mode

CAUSE: The specified I/O is with POD IO standard is connected to a termination control block that is not used in POD calibration mode. The termination atom in the OCT block should have the POD parameter set.

ACTION: Set a_oct_cal_mode in the termination atom that connects to the pin to A_OCT_CAL_MODE_POD.